Call Us : (800) 673-4102

Agilent / HP 8757A

Agilent HP 8757A Scalar Network Analyzer. 10 MHz to 60 GHz depending on detectors sold separately.
  • Agilent / HP 8757A for sale
Mouse move on Image to zoom
$1050.00 Sorry, Out of Stock

Model: Agilent / HP 8757A     Condition: Reconditioned

The 8757A is a microprocessor-based receiver capable of making scalar (magnitude only) reflection and transmission measurements over a frequency range determined by the external detectors used. It has a large screen for display of measurement results. It is programmable over the Hewlett-Packard Interface Bus (HP-IB). Whether or not the 8757A is controlled remotely over HP-IB, it can control a specific plotter and/or source throught the 8757 system interface. A measurement with the 8757A requires the connection of detector(s) and/or directional bridge(s) to the detector input on the front panel, and the use of a compatible RF/microwave source.

The 8757A is locally operated by front panel controls and by menu selection using "soft" keys adjacent to the CRT. It has four independent but identical measurement channels, allowing simultaneous viewing of up to four measurement parameters with independent resolutions. The standard instrument has three detector inputs while Option 001 has four detector inputs. The 8757A uses either AC or DC detection techniques in conjunction with its detectors. AC detection provides very stable measurements even with temperature variations and RF interference. DC detection should be used for modulation-sensitive devices (for example, non-linear amplifiers, narrow-band filters) and for devices that cannot be modulated (for example, oscillators).

  • Four independent display channels
  • Three inputs (four with Option 001)
  • Dynamic range:
    • With 11664A/E detector: +16 to ‑60 dBm
    • With 11664D detector: +10 to ‑50 dBm
    • With 85025A/B detector: +16 to ‑55 dBm (AC mode), +16 to ‑50 dBm (DC mode)
  • Sweep time (1, 2, 3, 4 traces) - Minimum sweep time and maximum number of display traces depend on horizontal resolution:
    • 101 points: 40, 50, 60, 70 ms
    • 201 pionts: 50, 75, 90, 100 ms
    • 401 points: 100, 100, 150, 200 ms
    • 801 points: 200, 250, N/A, N/A ms
    • 1601 points: 400, N/A, N/A, N/A ms
  • Sweep voltage (Sweep in): 0 to 10 V
  • Marker and Blanking typical voltage levels:
    • Blanked: +5 V
    • Unblanked: 0 V
    • Marker: -4 V
    • Active marker: -8 V
  • Scale resolution (independently controlled for each channel): 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 dB per division
  • Reference offset: ‑70 to +20 dBm (power), ‑90 to +90 dB (ratio)
  • Display resolution:
    • Vertical: 0.003 dB single input, 0.006 dB ratio measurement, 0.01 dB "Display Cursor"
    • Horizontal: 101, 201, 401, 801, 1601 data points
  • Averaging: 2, 4, 8, 16, 32, 64, 128, 256 successive traces may be averaged
  • Smoothing: 0.1% to 20% of the trace width
  • Rear panel connectors: Stop Sweep, DAC Out, ADC In
  • HP-IB interface
  • Interface function codes: SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT0, C0, E1
  • Transfer formats: ASCII strings, 16-bit integers
  • Programmable functions: All front panel functions, except power and CRT
  • SRQs (service interrupts): Front panel key pressed, soft key only pressed, operation complete (sweep or plot), syntax error, instrument self-test error, numeric entry completed, limit test failed, action requested not possible, knob activity, low battery voltage
Operation Manual
Power Cord
HP-IB Cable
Item Description
HP / Agilent 85025B HP Agilent 85025B Coaxial AC/DC Detector. 10 MHz to 26.5 GHz.
HP / Agilent 11664E Agilent HP 11664E 10 MHz to 26.5 GHz Scalar Detector. APC3.5. Works with 8755 8756, 8757 series network analyzers.
HP / Agilent 85025A Agilent HP 85025A Detector. 10 MHz to 18 GHz. Used with 8757 Series Network Analyzers. Type N connector.
Item Description Price
HP / Agilent 85027C Agilent HP 85027C - 10 MHz - 18 GHz Directional Bridge $1695.00
HP / Agilent 85025B HP Agilent 85025B Coaxial AC/DC Detector. 10 MHz to 26.5 GHz. $1295.00
HP / Agilent 85027B Agilent HP 85027B Directional Bridge, Complete, 10 MHz to 26.5 GHz for 8757 series analyzers $2695.00
Agilent / HP 8757C Agilent HP 8757C / 001 Scalar Network Analyzer with optional fourth detector input $1095.00

Similar Products

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

Agilent / HP 8757A

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.