Call Us : (800) 673-4102

HP / Agilent E4418A

Agilent HP E4418A - RF Power Meter. AKA EPM-441A.
  • HP / Agilent E4418A for sale
Mouse move on Image to zoom
$525.00 In Stock! 

Model: HP / Agilent E4418A     Condition: Reconditioned

RF Power Meter including sensor cable.  Sensor sold separately.  AKA EPM-441A. 

Description

The E4418A is a low-cost, high-performance, single-channel, programmable power meter. It is fully compatible with the 8480 series and the E-series power sensors (except the E9320A family). Depending upon which sensor is used, the E4418A can measure from -70 dBm to +44 dBm at frequencies from 100 kHz to 110 GHz.

Designed for bench and automatic test equipment (ATE) use, the E4418A makes fast (up to 200 readings per second with E-series sensors), accurate and repeatable power measurements.

  • Fast measurement speed (up to 200 readings per second, over the GPIB, with E-series sensors)
  • Speed improvement of x2 using the 8480 series power sensor (compared to 437B)
  • No range-switching delays with 8480 series sensors, and only one fast-range switch point with E-series sensors
  • High-resolution display with backlighting for a wide viewing angle of displayed data
  • Save and recall of up to 10 instrument states
  • GPIB connector for remote control of all functions
  • Code compatibility with 437B
  • Conformity to CE and CSA standards
  • For complete details, click on the Data Sheet link

Users Manual (QR Link)
Programming Manual (QR Link)
Power Cord
Sensor Cable
Boot/Handle Set (installed)
Item Description
HP / Agilent 8482A Agilent HP 8482A RF Power Sensor. 100 KHz to 4.2 GHz. -30 to +20 dBm.
HP / Agilent 8484A / 11708A Agilent HP 8484A / 11708A High Sensitivity RF Power Sensor. 10 MHz to 18 GHz. -70 to -20 dBm.
HP / Agilent 8481A Agilent HP 8481A - 10 MHz to 18 GHz RF Power Sensor, 1 uW to 100 mW (-30 to +20 dBm)
HP / Agilent 8482B Agilent HP 8482B RF Power Sensor. 100 KHz to 4.2 GHz. 0 to +44 dBm (25W). Includes 8498A attenuator.
HP / Agilent 8487A Agilent HP 8487A - 80 MHz to 50 GHz RF Power Sensor. 1 uW to 100 mW (-30 to +20 dBm). Includes type N adapter
HP / Agilent 8485A Agilent HP 8485A - 50 MHz-26.5 GHzPower Sensor, -30 to +20 dBm
HP / Agilent 8481B Agilent HP 8481B - RF Power Sensor with 8498A attenuator, 10MHz to 18GHz, 1mW to 25W
HP / Agilent 8485D w/ 11708A Agilent 8485D - 50 MHz - 26.5 GHz Power Sensor with 11708A
HP / Agilent 8481H Agilent HP 8481H - RF Power Sensor, 10 MHz to 18 GHz, -10 to +35 dBm
Pelican Pelican 1550 Pelican® Case 1550 with Foam- Black (Pelican 1550 Case)
Pelican Pelican 1520 Pelican® Case 1520 with Foam- Black (Pelican 1520 Case)
HP / Agilent 8481D Agilent HP 8481D with 11708A Attenuator Power Sensor 10 MHz to 18 GHz, -70 to -20 dBm
HP / Agilent 8482H Agilent HP 8482H RF Power Sensor. 100 KHz to 4.2 GHz. -10 to +35 dBm
HP / Agilent 8485D w/ 11708A Agilent HP 8485D - Power Sensor 50 MHz to 33 GHz with Opt 033. -70 to -20 dBm. Includes 11708A Attenuator.
HP / Agilent 8483A Agilent HP 8483A - Power Sensor. 75 Ohm, .1 to 2000 MHz, Includes 50 Ohm Minimum Loss Adapter.
Agilent / Keysight E4412A Agilent Keysight E4412A Wide Dynamic Range Power HPSensor,10 MHz to 18 GHz.
Agilent / Keysight 8487D Agilent HP Keysight 8487D - 50 GHz Power Sensor with 11708A reference attenuator.
Agilent / Keysight N8487A Keysight Agilent N8487A Thermocouple Power Sensor. 50 MHz to 50 GHz. -35 dBm to +20 dBm. Compatible with EPM, EPM-P), and P-Series power meters.
Agilent / HP 8481B HP Agilent 8481B RF Power Sensor 10MHz to 18GHz, 1mW to 25W. Includes Weinschel 30 dB attenuator instead of the originally supplied Agilent attenuator.
Agilent / HP 8482B HP Agilent 8482B RF Power Sensor 100kHz to 4.2GHz, 1mW to 25W. Includes Weinschel 30 dB attenuator instead of the originally supplied Agilent attenuator.
Agilent / Keysight ECP-E18A Agilent HP ECP-E18A Wide Dynamic Range Power Sensor,10 MHz to 18 GHz.
Item Description Price
HP / Agilent Option 002 for E4418A Agilent HP Option 002 for E4418A $135.00
HP / Agilent Option 001 for E4418B Agilent HP E4418B - Rechargeable Battery Option 001 $225.00

Similar Products

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

HP / Agilent E4418A

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.