  • The Modulation Meter AMM20002Q is a portable full featured modulation meter. It measures signals in the 150 kHz to 2.4 GHz frequency range. This range covers virtually all radio services in MF, HF, VHF, und UHF bands. A microprocessor automatically locks onto the strongest carrier frequency. The keyboard is used for manual tuning.
  • A built-in digital self-calibration source is used for AM, FM, and PM measurements. An accuracy of better than 1% is achieved using the built-in digital self-calibration source. The modulation bandwidth is 10 Hz to 300 kHz. This allows for measurements on high data rate systems. Modulation measurement capability is 99% AM, 500 kHz pk FM, and 50 rad PM. The large FM deviation is useful when measuring wideband telemetry systems.
  • The modulation meter has a low noise figure. This maximizes the resolution for narrowband and unwanted modulation measurements. The meter is equipped with three high pass and four low pass filters, an FM de-emphasis mode, and peak or true RMS level modes. These features provide post carrier detection signal conditioning. The display can be set to give absolute or relative values. These values can either be linear or dB. Measurements with a peak hold are available for burst capture. When making residual noise measurements, digital averaging can be selected.
  • The meter can also be used as a frequency counter. Resolutions of 10 Hz an 0.1 Hz can be expected over the RF and AF ranges respectfully. A rear panel AF input jack enables baseband signals for level and frequency to be analyzed. A TCXO reference is fitted as a standard with an aging rate of ±E-6 per year.
    Maximum sensitivity for modulation and frequency measurement is ¿30 dBm. Carrier levels can be measured in dBm or mW over a range of ¿6 dBm to +20 dBm. Carrier levels up to +30 dBm can be measured using an external 10 dB attenuator pad (maximum continuous power 1 W). Excess power protection is provided at the instrument RF input for signals up to 25 W and down to 250 mW.
  • Manual operation of the meter is performed using the keyboard. The keyboard is a sealed tactile membrane front panel with an RFI shield laminated in it. The internal RAM can store 99 user defined setups. This RAM also allows rapid switching between predetermined tests. Individual memories are available for recall, store, and protect. All measurements are shown on a highly visible 32-character alphanumeric LED. A 20-segment analog LED bar graph is useful when viewing peaks and trends.
  • Remote control operations are available through a GPIB interface. It can put settings and output measurements. This is ideal for use in automatic test systems.
  • Please contact our sales department for more information.

    Contact Info

    Please let us know how we can contact you.

    Additional Info


    In-Stock Notification Request Sent

    Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

    Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

    Error Sending Request

    We are very sorry but an error on the server is preventing your request from being processed.

    Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

    We would also greatly appreciate it if you could provide us with this error code: 999

    Unable to Process Request

    Your offer was received but we are unable to process it for the following reason:
    ???

    Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

    Offer

    AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

    Wayne Kerr AMM20002Q

    $ .00

    Contact Info

    Requirements

    Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

    Reduced Warranty Period:
    Do you require manuals and accessories for the instrument?
    Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

    Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

    Additional Info


    Equipment Offer Sent

    Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

    Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

    Error Sending Request

    We are very sorry but an error on the server is preventing your request from being processed.

    Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

    We would also greatly appreciate it if you could provide us with this error code: 999

    Unable to Process Offer

    Your offer was received but we are unable to process it for the following reason:
    ???

    Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.