Call Us : (800) 673-4102

Stanford Research Systems / SRS SR630

Stanford Research (SRS) SR630 - 16 Channel Thermocouple Monitor. Monitors type B, E, J, K, R, S and T thermocouples
  • Stanford Research Systems / SRS SR630 for sale
Mouse move on Image to zoom

Datasheets

$649.00 Sorry, Out of Stock

Model: Stanford Research Systems / SRS SR630     Condition: Reconditioned

SR630 Thermocouple Monitor

The SR630 is a 16-channel thermocouple monitor designed to read, scan, print and log temperatures or voltages. You can use any one of seven standard thermocouple types to read temperatures from -200 °C to +1700 °C. For remote monitoring applications, the SR630 can time-stamp and store up to 2000 readings in non-volatile memory for later analysis.

Temperature readings from the SR630 can be viewed on the front panel or queried via the instrument's standard RS-232 or GPIB interfaces. In addition, the standard Centronics printer port provides convenient hardcopy output in either tabular or strip-chart format.

Voltage Monitor

The SR630 can also be configured as a 16-channel DC voltmeter with full-scale ranges from 30 mV to 100 V (1 mV resolution). As a voltmeter, the unit has 0.05 % accuracy and 1 µV input offset drift. Each channel can be set independently to monitor either temperature or voltage, giving the SR630 even more flexibility in your application. Four rear-panel outputs are also available to provide a voltage proportional to the temperature of the first four input channels. The voltage outputs can be used to drive recorders or to control external instrumentation.

Inputs

Sixteen screw-terminal inputs are mounted on a rear-panel isothermal block for cold junction compensation. The isolated differential inputs have a 250 V breakdown level, allowing the SR630 to tackle difficult applications such as temperature profiling of electrically live equipment. Each of the 16 channels may be independently set to display in units of °C, °F, K, mV or V. Similarly, thermocouple type, nominal temperature, temperature limit, and alarms may be uniquely set for each channel, providing complete flexibility in the configuration of the instrument. Access to any channel parameter is provided through the front panel or via the computer interfaces. The SR630 can store up to nine entire instrument configurations including thermocouple type and temperature limits for all 16 channels.

Outputs

There are four analog outputs that are proportional to the readings on channels one through four. Both the slope (m) and offset (b) of the equation, Vout = ±mX + b, are changed by setting the nominal temperature and chart span for the corresponding channel. X is either temperature or voltage, depending on the setting for each channel.

You may use the analog outputs to drive chart recorders or they can provide a feedback signal for proportional temperature control systems. They may also be used as fixed-level, analog control signals (set via the computer interfaces).


 Tabular Output

Alarms

Each channel can be programmed individually with an upper and lower temperature limit. An audio alarm and a relay closure indicate when any channel exceeds its preset temperature or voltage limits. The front-panel LED display will indicate which channel has exceeded its limit.

Data Logging

An internal, battery backed-up clock/calendar is used to time-stamp temperature readings. The SR630 can be set to scan, time-stamp, and record data on up to 16 channels at intervals from 10 to 9999 seconds. Data is either sent immediately to the printer, or stored in the internal 2,000 point buffer for output at a later time (via GPIB or RS-232).

Built-In Printer Interface

A standard Centronics printer interface makes it simple to get hardcopy output of temperature or voltage scans. Two hardcopy formats are provided. The SR630 can print a continuous strip chart showing up to 16 different temperatures ( see example below). In addition, data can be printed in a tabular format (see example below and left) which logs the time, date, and temperature or voltage for each channel.


Strip Chart Output

Analog Multiplexer

The SR630 can also function as a 1:15 analog multiplexer. Any of the first 15 input channels can be switched out t

Please contact our sales department for more information.

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

Stanford Research Systems / SRS SR630

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.