The Guardian 1030 AC/DC/IR Hipot Tester has all the features of the Guardian 1010 with the addition of DC hipot and IR measurement capabilities. The test voltage can be programmed in the range from 50VDC to 6kVDC with a resolution of 1V. The maximum total current is 10mA. The IR measurement range is from 0.1M ohm to 50G ohm with test voltages from 50 to 1000VDC.
The Guardian 1030S AC/DC/IR/SC Hipot Tester has all of the features of theGuardian1030 plus eight HV Scan Channels for multi-point testing
Quick Discharge: In both the DC hipot and IR tests the device under test is discharged back through the HV transformer. This technique results in a rapid and safe discharge.
Ground Continuity Check: All of the Guardian 1000 Series units have a ground continuity check feature to determine that the resistance, between the ground blade of the power cord and any exposed metal on the product, is less than 1 ohm.
QuadTech Guardian 1030S