Call Us : (800) 673-4102

Lambda GEN60-55

TDK-Lambda GEN 60-55-IS510-3P208 Genesys DC Power Supply 0-60V, 55A. 3.3kW. Requires 190-240V 3P input. Includes isolated analog programming option.
  • Lambda GEN60-55 for sale
Mouse move on Image to zoom

Datasheets

$1695.00 In Stock! 

Model: Lambda GEN60-55     Condition: Reconditioned

The Genesys family of programmable AC/DC power supplies sets a new standard for flexible, reliable, power systems in OEM, Industrial and Laboratory applications. Now available in more power levels (750W, 1.5kW, 2.4kW, 3.3kW, 5kW, 10kW and 15kW) and with output voltages from 8 to 600V and current up to 1,000A. Active PFC, Standard RS-232/RS-485 and world-wide inputs head a long list of standard features.

This member of the Genesys product family of programmable switching power supplies provides high power density, low ripple and a complete set of user-friendly interfaces. In addition to high power density, popular worldwide three phase inputs are available. Inputs are available for 208VAC or 400VAC - three phase, 50/60Hz with Active Power Factor Correction of 0.92-0.94. This assures operation in difficult AC environments and meets European EMC requirements.

A user-friendly front panel provides reliable control through encoders selectable for fine or course adjustment (~6 or 30 turns) and four digit LED Voltage and Current meters. Adjustable OVP, UVL and Current Foldback provide further flexibility. Their set values may be previewed on the front panel display, even with Output Off. The Foldback may be set to latch output off if desired for safety.

All Genesys platforms include several other important features. Up to four like units may be connected in parallel and user configured for the Master to Program and Monitor the total current of the group. Thus, four units can appear as a single 3kW to 60kW power supply, increasing flexibility for system designers.

Significant safety features include Safe Re-Start and Last Setting Memory. With Safe Re-Start, the user can select whether the Genesys¿ power supply returns to previous settings after power off, or returns to zero (safe) output, waiting for user instructions. Last Setting Memory retains settings of output voltage and current, remote or local mode, OVP and UVL, Foldback, Baud Rate and Start-Up Mode, without battery. Front Panel controls also include Output On/Off and Local/Remote Digital selection. The Front Panel may be locked locally or by software command.

All Genesys products includes standard, embedded 16 bit RS-232/RS-485 digital interface. Through this digital interface up to 31 power supplies may be controlled in daisy chain over the RS-485 line. Analog remote programming is user selectable 0-5V or 0-10V via DIP switches on the rear panel. The design of Genesys¿ power supplies is highly modular. SMT technology provides high reliability.

Among standard digital features, Multi-Drop allows an IEEE or LAN Master to control standard Slaves over RS-485, avoiding the cost of a GPIB or LAN board in every slave power supply. Up to 31 may be addressed over the RS-485 lines of Master and Slaves.


 

Technical Manual (QR Link)
DB25 Connector
Output Hardware Set (iinstalled)
Serial Link Cable
Output Shield (installed)
Strain Relief (installed)
AC Input Cover (installed)
AC Input Plug (installed)
Feet (Qty 4)
Sense Lead Set (Installed)
Rack Mount Kit (Installed)
DIP Switch Cover (Installed)
Item Description Price
Lambda LAN Option LAN Option for Lambda Genesys 5kW DC Power Supplies. Sold installed only. GEN5000 $295.00
Lambda IEEE488 Option IEMD Option GPIB IEEE488 interface for Lambda Genesys DC Power Supplies. Sold installed only. $295.00
Lambda IS510 Lambda IS510 Voltage Programming Isolated Analog Interface for Genesys power supplies. Not sold separately. $100.00

Similar Products

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

Lambda GEN60-55

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.