Call Us : (800) 673-4102

Hipotronics HD106-A

Hipotronics HD106-A 0 - 6 KV DC, 0 - 5 KV AC Hipot. Overload sensitivity Adjustable from 0.5 mA to 5.5 mA. Newer vintage unit, 120V AC line voltage.
  • Hipotronics HD106-A for sale
Mouse move on Image to zoom

Datasheets

$1395.00 Sorry, Out of Stock

Model: Hipotronics HD106-A     Condition: Reconditioned

0 - 6 KV DC, 0 - 5 KV AC Hipot. Overload sensitivity Adjustable from 0.5 mA to 5.5 mA

The 100 Series AC/ DC Hipots are accurate, durable instruments designed to perform hipot tests on all types of electrical products, systems, and components. They are designed to perform AC and DC dielectric tests.

Features

  • Recessed, Locking High Voltage Connection - Minimizes user accessibility to high voltage. Also prevents the output lead from being accidentally removed from the high voltage outlet.
  • Interlock Provision - Allows easy installation of any type of safety switch into the interlock circuit. Breaking this circuit will disable the high voltage output.
  • Over Current Protection with Manual Reset - Protects the test object from excess current levels by rapidly shutting down the high voltage. The overload sensitivity is continuously adjustable to allow testing of various test loads.
  • Audible/Visual Alarms - The audible and visual alarms provide a clear indication of an overload situation or a go/no-go failure.
  • Zero Start Interlock - Ensures that the voltage control adjustment is at zero before the high voltage transformer can be energized. This feature ensures that the high voltage is not applied instantly to the object under test, which is potentially harmful in certain applications.
  • Gravity Operated Solenoid - Discharges the object under test when a failure occurs in that object or when the power is turned off.
  • Output Connected Voltmeter - Ensures accurate voltage measurement regardless of output loading.

Benefits

  • Two Tests in One Unit - Eliminates need for purchasing separate AC and DC Hipot.
  • Meets Industry Speciications - Tests to most UL, CSA, VDE, IEC, MIL, BSI, BABT and other industry standards for Dielectric Withstand Testing.
  • Rack Mountable - Easy installation into a 19" rack.

Applications

The most common applications are for testing of:

  1. high voltage tubes
  2. capacitors
  3. transformers
  4. wire and cable
  5. coils and chokes
  6. motors and generators
  7. connectors
  8. medical devices
  9. appliances
  10. switches and relays

 

** NOTE ** - This item may require palletized shipping.  Contact Sales for details. 
Palletized shipments will not calculate properly during online checkout. 
Clients may proceed with online orders and our Sales staff will contact you regarding
the shipping details.
Users Manual
High Voltage Lead
Ground Lead
Outer Cage/Rack (installed)

Similar Products

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

Hipotronics HD106-A

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.