Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.
Air Insulated. The LT Series features "air" as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.
Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.
Low Ripple. Ripple is less than 0.03% of rated voltage at full load.
Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 0.05% from short circuit to rated voltage.
Front Panel Controls (Analog and Digital Versions.) Separate 10-turn controls with locking vernier dials are used to set voltage and current levels. A high voltage enable switch and an AC power on/off switch complete the panel controls. L.E.D.'s indicate when high voltage is on, the output polarity, and whether the supply is operating in a voltage or current regulating mode. For the blank panel version, only a power on/off switch is provided on the panel.
Small Size and Weight. LT Series power supplies occupy only 8.75 inches of panel height. Net weight is less than 47 pounds.
Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.
(From 5 to 100% rated voltage. All units operate down to zero output with very slight degradation of performance.)
Input: 198-264 V RMS, single-phase, 48-63 Hz, <20 A. A 3-position terminal block with protective cover is provided.
Efficiency: Typically 85% at full load.
Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.
Stored Energy: <15 Joules, 60 kV; <30 Joules, 125 kV.
Voltage Regulation: Better than 0.005% for specified line variations and 0.005% + 1 mV/mA for load variations.
Ripple: <0.03% of rated voltage + 1 V RMS at full load (0.1% for 150kV).
Current Regulation: Better than 0.05% from short circuit to rated voltage at any load condition.
Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage. Accuracy, 1% reading + 1% rated.
Current Monitor: 0 to +10 V equivalent to 0 to rated current. Accuracy, 1% reading + 0.1% rated for single polarity, 1% reading + 0.15% rated for reversible polarity.
Stability: 0.01% per hour after 1/2 hour warmup, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant: 50 ms typical to 60 kV (400 ms for higher voltages) with a 30% resistive load using either HV on/off or remote programming control.
Temperature Coefficient: 0.01% per degree C.
Ambient Temperature: -20 to +40 degree C, operating; -40 to +85 degree C, storage.
Polarity: Available with either positive, negative, or reversible polarity with respect to chassis ground.