Call Us : (800) 673-4102

EIP 548B

EIP 548B - 10 Hz to 26.5 GHz Microwave Frequency Counter. Includes option 08 (GPIB) and option 06 (frequency extension capability). Contact sales for available timebase upgrades.
  • EIP 548B for sale
Mouse move on Image to zoom

Datasheets

$1495.00 Sorry, Out of Stock

Model: EIP 548B     Condition: Reconditioned

10 Hz to 20 GHz / 10 Hz to 26 GHz
The combination of accuracy, simple operation, and the widest range of standard features and options available in a microwave counter makes the 545B/548B family the best choice for your R&D lab or production test bench. Wherever a microwave counter has multiple duties and a variety of applications to meet, only a full function counter with YIG-tuned preselection can provide the capabilities that you need.

Features at a glance:
Keyboard controlled frequency limit selection
Power Measurement to 0.1 dB resolution
Power Measurement accuracy to ±0.5 dB typical
-30 dBm sensitivity
200 Watt (+53 dBm) peak damage protection
10 dB automatic amplitude discrimination
200 ms acquisition time
Up to 800 MHz/sec tracking speed
20 MHz P-P FM tolerance up to a 10 MHz rate

Frequency Extension to 110 GHz
Option 06 provides the ability to extend the frequency range of your 548B, in bands, up to 110 GHz. Remote sensors allow you to reach out to connect to virtually any wave guide system without the complications of the additional plumbing necessary to bring the signal to your counter. A wide selection of sensors provides measurement capability in the wave guide band that you are working in now, and the flexibility to change as your application changes without having to purchase another counter.

Frequency Limits
Automatic amplitude discrimination enables the 545B/548B counters to automatically select and measure the input signal with the highest level, and ignore all other harmonics and other spurious signals that are present. "Frequency Limits" extend this signal selection capability by allowing you to select upper and lower limits, The counter will measure the frequency and power level of only the highest level signal within these limits - even if there are higher level signals present at the counters input. This gives you the ability to measure the frequency and power of a low level signal (such as a harmonic) even when a signal of much higher level (the fundamental) is present.

Power Measurement
The 545B/548B family of microwave counters offers the optional ability to simultaneously measure both the frequency and power level through the same input. This often eliminates the need for a separate microwave power meter. With the 25 MHz bandwidth of the YIG tuned preselector, power measurement is made only of the displayed signal, not of its harmonics or other signals present. Thus you can simultaneously measure and display both frequency and power of individual signals in a multi-signal environment. Easy keystroke entry of power offsets can be used to measure power deviation from a reference, or to compensate for losses in external hookups such as cable and attenuator losses.



Frequency domain analysis can be accurately and quickly performed by utilizing the counter's selective frequency and selective power measurement capabilities

Specifications at a glance:
Frequency Range

Band 1: 10 Hz to 100 MHz
Band 2: 10 MHz to 1 GHz
Band 3: 1 GHz to 20 GHz (545B) or 26 GHz (548B).
548B expandable to 110 GHz.
Sensitivity
Band 1: 25 mV RMS
Band 2: -20 dBm
Band 3: -30 dBm to 12.4 GHz,
-25 dBm to 20 GHz,
-20 dBm to 26.5(548B)
Acquisition Time
Normal Mode : 200 ms
CenterFrequency Mode: 20 ms
Power Measurement
Range : Same as Band 3
Accuracy : ±0.5 dB typical

Operation Manual (QR Link)
Power Cord
Item Description
EIP 590 Frequency Extension Cable set for 538, 548, 578 series counters with external mixing capability. Option 91 adds 26.5 to 40 GHz remote sensor.
Item Description Price
EIP Remote Sensor EIP 40 GHz remote sensor & cables for EIP 548A/B $400.00

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

EIP 548B

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.