Baker AWA12000

Megger SKF Baker AWA12000 99-AWAIV-12EHO/2 Digital Winding Tester with High Output Option. 0-12,000V Surge / Hipot Automated surge / step-voltage / resistance analyzer for testing static (or off-line) motors. Series IV.
  • Baker AWA12000 for sale
Mouse move on Image to zoom

Datasheets

Call for price Sorry, Out of Stock

Model: Baker AWA12000     Condition: Reconditioned

Automated surge/step-voltage/resistance analyzer for testing static (or off-line) motors

The SKF Static Motor Analyzer – Baker AWA-IV series of electric motor analyzers are fully-automated, user-programmable instruments that deliver reliable testing of motors with repeatable results, regardless of user. These easy-to-use instruments perform a wide range of electrical tests, including surge, DC hipot, step voltage, continuous ramp, meg-Ohm and winding resistance tests. Models include the Baker AWA-IV 12 kV, Baker AWA-IV 12 kV HO, Baker AWA-IV 6 kV, Baker AWA-IV 4 kV, and Baker AWA-IV 2 kV. 
  • Improved testing capabilities from previous Baker AWA versions: continuous ramped step-voltage, enhanced reference surge waveform, improved PI/DA test, improved DC hipot, improved resistance test, more sensitive surge test

Designed for fast, reliable, automated testing

The SKF Static Motor Analyzer - Baker AWA-IV is designed to perform automated sequences of a user-selected array of motor insulation tests. The analyzer's embedded computer conducts the tests, stores the results and continuously monitors voltage levels while testing. If the computer detects a weakness in the insulation during a given test, the test is interrupted, the operator is alerted and all test parameters at the time of the interruption are reported. This instrument performs this automated operation in microseconds, and with a higher degree of precision and safety than can be achieved through manual test methods.

Pre-programmed in the office and implemented in the field

The Baker AWA-IV is the only high-voltage tester that can be programmed to perform a specific set of insulation tests by a user prior to being in the field, then used as programmed in the field. A user's work orders or routes often define which motors to test, the order of execution and parameters for each test, such as voltages, duration and pass-fail limits. Operators can program the unit to conduct tests in the field simply by connecting to the analyzer. This allows users to minimize time and effort involved with repeat maintenance test sequences performed manually, and improves reliability of testing procedures.

Save testing results

When testing is complete, results can be saved as part of each motor's permanent test record. This type of documentation is critical to successful reliability programmes. With the AWAIV, test results are collected, stored, recalled and managed using a standard Microsoft Access® relational database format. The Baker AWA-IV produces .rtf type test data files, so a variety of desktop computer word processing software programmes can be used. These database files make it easy to transfer information to common maintenance management software or other database tools. MS Access® is ODBC compliant.

Incorporates advanced inter-turn capabilities in a field portable instrument

Computer control and waveform monitoring are enhancements above manually controlled instruments. As with the DC HiPot test, the Baker AWA-IV begins surge generation at low voltage. Each pulse applied to the winding is digitized and the resultant waveform is compared to previous waveforms to detect any signs of turn-to-turn weaknesses. Comparison is done by the patented Pulse to Pulse Error Area Ration (PP-EAR) technique. This method is sensitive to less than a one percent variance between coils. In addition, shorts among windings in parallel can be located, something that was never possible before by visually comparing waveforms. With the Baker AWA-IV, fewer pulses are applied to the winding, reducing the power required to perform the surge test. Since each and every pulse is analyzed, it becomes the new reference waveform as test voltage is increased up to the specific withstand level. If no turn-to-turn weakness is detected, the final pulse waveform is stored as the reference waveform for all subsequent tests.
  • -->
    User Manual
    Quick Start Guide
    Power Cord
    Keyboard w/Integrated Mouse
    Test Lead Set (installed)
    Resistance Test Lead Set

Similar Products

Contact Info

Please let us know how we can contact you.

Additional Info


In-Stock Notification Request Sent

Your request to be notified when this product is back in stock has been sent to our sales department. We will notify you as soon as this item is available for purchase.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Request

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

Offer

AccuSource Electronics is always happy to consider reasonable offers on our test instruments. Please enter your offer below for consideration.

Baker AWA12000

$ .00

Contact Info

Requirements

Our normal service includes 90 day warranty, all standard accessories and manuals, and restoration to "nearly new" condition. Discounts may be offered for reduced service levels. Please let us know which of these you would be willing to consider for the price discount.

Reduced Warranty Period:
Do you require manuals and accessories for the instrument?
Will you accept an instrument with minor cosmetic and physical flaws if it operates properly?

Are you willing to prepay your order by check or wire transfer to avoid credit card fees?

Additional Info


Equipment Offer Sent

Your offer has been sent to our sales department for review. You should expect a response within one business day or less.

Thank you for allowing us the opportunity to assist with your test equipment needs. We hope to earn your business.

Error Sending Request

We are very sorry but an error on the server is preventing your request from being processed.

Please contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.

We would also greatly appreciate it if you could provide us with this error code: 999

Unable to Process Offer

Your offer was received but we are unable to process it for the following reason:
???

Please correct the issue indicated and resubmit or contact us via email or toll free at (800) 673-4102 and we will be happy to assist you with this request.